1. Operation instructions:
Load the battery correctly according to the battery bin instructions, and place the scale body on a smooth and windless table.
Key description:
ON/OFF: Switch on or off
PCS: count key
TARE: Peeling key
UNTS/MODE: indicates the unit conversion key
1, the power button ON/OFF boot, wait three seconds to display 0 or 0.0 or 0.00 or 0.000
2. Put all the items to be weighed on the pan and read them after the value is stable
3, press the unit conversion key to change the weighing unit
4. Press the power button to shut down the machine
2. Unit conversion key UNTS/MODE
Press this key to select the unit of weight you need, there are a variety of units to convert.
Weight unit conversion value:
1ct/ carat =0.19997g 1oz/ ounce =28.3495g
1dwt/ Pound =1.5552g 1ozt/ Troy ounce =31.1034g
1gn/ gram =0.0648g 1tl/ station =37.4999g
9 speed unit conversion: gram, ounce, Troy ounce, pound, gring, carat, milliliter, two pounds (Chinese version only)
Three, buckle weight/peel TARE
1, boot to zero;
2, the buckle weight on the pan;
3, press the peel key (TARE key or T key) to display 0.0 or 0.00, indicating that the weight has been deducted
4, and then put in the weight of the item, the reading at this time is the net weight of the item
Fourth, calibration: calibration must have the corresponding weights
Kitchen scale, jewelry scale school scale method:
Scale mode:
1. In shutdown MODE, hold down the [TARE] or [T] key and then long press the [ON/OFF] key to power on for 2 seconds to enter the internal code test state. At this time, press the [Mode], [UNIT] or [M] key to enter the calibration mode. "CAL" is displayed.
2. In the weighing MODE, long press [Mode], [UNIT] or [M] key to enter the calibration mode, then "CAL" will be displayed.
Calibration method:
After entering the scale with one of the above two modes to display "CAL", press the [MODE] or [UNIT] or [M] key again, the word "CAL" will be displayed, and it will blink several times and display the calibration weight. Put the corresponding weight on the pan, and stabilize for 3~4 seconds to complete the weight calibration. After "PASS" is displayed, press [ON/OFF] to shut down and complete the calibration.
Electronic measuring spoon calibration method:
Scale mode:
In off MODE, press the TARE key to power it on, release it, and then press the other two keys simultaneously (MODE/HOLD). When a string of numbers is displayed. Then let go. Click the MODE key.
1, take 300g/0.1g as an example (need to be corrected twice) and then 150g characters will be displayed. Then put 150 grams of weight on it. Wait for the number to display 300g. Then put the 300g weight, when the screen shows PASS, long press the TARE key to shut down, and then take down the weight. Then turn on the weight, check the accuracy of the scale.
2, take 500g/0.1g as an example (need to be corrected twice) and then 200g characters will be displayed. And then put 200 grams of weight on it. Wait for the number to show 500g. Then put 500g weight, when the screen shows PASS, long press the TARE key to shut down, and then take down the weight. Then turn on the weight, check the accuracy of the scale.
5. Counting function (only for some products)
Under the normal weighing state, place a certain number of samples on the pan (the system pre-sets 25, 50, 75, 100 four sample quantities for choice) that need to be counted, hold down the "PCS" key and do not let go. After 2 seconds, the display screen displays the number of samples, and then release the "PCS" key. Press the "MODE" key (or "M" key, "UNITS" key) to switch different sample quantity. Press the "PCS" key to confirm the sample quantity after selection, that is, enter the counting state; If the sample quantity needs to be changed, it can be reset according to the above steps; Press the MODE key (or the M key or UNITS key) in the counting state. The system exits the counting state and returns to the normal weighing state to display the weight value.
Vi. Use matters:
1, the maximum weighing of this product should not exceed its maximum range +2%.
2, overload will permanently damage the product.
3, the product can not be exposed to extremely cold or extremely hot environment, in the normal environment the product can work well, please before use, let the product adapt to a new environment for at least one hour.
4, before use, start weighing with weights several times to preheat the internal components of the scale, which will make the weighing more accurate.
5, put the product in a clean environment, dust, moisture, vibration, airflow, or electromagnetic interference will have an adverse effect on the stability and accuracy of the product.
6, to be handled lightly, the item should be gently placed on the pan when weighing, so as not to weigh inaccurate or damage the internal parts of the scale.
7, because the product is a high precision product, so the use of very careful to avoid vibration or drop.
8. Use on a stable and windless horizontal surface.
7. Troubleshooting:
The top factors for inaccurate weighing or failure are low battery power, incorrect calibration, overload or operation on a non-horizontal plane. Please pay attention to the above mentioned points in order to properly use and maintain your product.
1, do not display or display insufficient power symbol [lo] need to change the battery;
2, [EEEEE] overload, should immediately remove the loaded items;
3, [o_ld] due to the wrong operation of the scale's internal core components damaged (such as impact, drop or overload), please try to re-calibrate, if the sensor is not seriously damaged, then re-calibrate can be used.
4, display 88888, please work in a vibration-free, stable plane.
8. Buyer's Notice
1. All products of the company are shot in kind, due to the different resolution of the light source or computer monitor, resulting in a little chromatic aberration, please use the physical object as the main. Color difference has always been an unavoidable problem in network trade, we are also trying to control, please agree to buy again.
2. Within seven days from the date of receipt of the electronic scale machine, if you are not satisfied, please keep the outer packaging intact, complete accessories, no wear and tear of the machine, you can return the matter. If there is a quality problem within 7 days, the replacement (your machine must ensure that its appearance, shell, display screen, mirror, pan and original stainless steel surface (if any) are not worn and lost, the accessories and fuselage are fully labeled, and the packaging is well preserved).
3. Electronic scale host non-human damage quality problem warranty for one year.
4. Warranty service is only valid under normal use, all man-made damage (such as: user's own disassembly, water immersion, not according to the manual use, due to other accidents caused by electronic scale damage, maintenance and modification without the company's approval, upgrade, etc.), are not within the scope of free warranty.
5. The products sold by the company are genuine, but not perfect and impeccable, please carefully measure according to the market price and baby description, to ensure that a price is a price.
6. If customers find any quality problems or other problems after receiving the products, please contact us in time. We will try our best to meet every customer. Good reputation does not come easily, we cherish it very much, but also hope to get your understanding and support. Thank you!